Pisces
Technical Specifications |
||
Display | ||
: | 12.1” TFT/LED/LCD Touch screen | |
Resolution | : | 800 x 600 |
Number of traces | : | 10 waveforms |
I/O | ||
LAN | : | 1 Standard RJ45 port |
WLAN | : | IEEE 802.11b/g/n |
USB | : | 2 USB connectors |
SD | : | 1 SD card socket (Optional) |
VGA | : | 1 VGA monitor connector (Optional) |
Output | : | 1 connector for Nurse call, Defib Sync Analog Output |
ECG | ||
Lead type | : | 3 Lead, 5-Lead, 12-Lead |
ECG waveform | : | 2 Channels, 7 Channels, 12 Channels |
Display sensitivity | : | 2.5mm/mV (x0.25), 5mm/mV (x0.5) 10mm/mV (x1.0), 20mm/mV (x2.0) |
Wave sweep speed | : | 6.25mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s |
Bandwidth | : | Diagnostic mode :
0.05Hz~100Hz Monitor mode: 0.5Hz~40Hz Surgery mode: 1Hz~20Hz Strong filter mode: 5Hz~20Hz CMRR>100dB |
Notch | : | 50/60Hz notch filter can be set to on or off Differential input impedance>5MΩ |
Electrode polarization voltage range | : | ±400mV Baseline recovery time<3s after defibrillation (in monitor and surgery mode) |
Calibration signal | : | 1mV (peak-peak), accuracy ±3% |
RESP | ||
Measurement method | : | Thoracic electrical bioimpedance |
Measuring lead | : | Lead I, II |
Wave gain | : | x0.25, x0.5, x1, x2 |
Respiratory impedance range | : | 0.5-5Ω |
Baseline impedance | : | 500-4000Ω |
Gain | : | 10 grades |
Scan speed | : | 6.25mm/s, 12.5mm/s, 25mm/s |
TEMP | ||
Accuracy | : | ±0.1⁰C or ±0.2⁰C ( without probe ) |
Measurement range | : | 0~50⁰C ( 32~122⁰F ) |
Channel | : | Two channels |
Resolution | : | 0.1⁰C |
Parameters | : | T1, T2 and TD |
SpO2 | ||
Measurement range | : | 0-100% |
Resolution | : | 1% |
Accuracy | : | ±2% ( 70-100%, Adult/Paediatric); ±3% (70-100%, Neonate); 0-69%, unspecified |
Refreshing Rate | : | 1s |
Masimo SET SpO²(Optional) | ||
Measurement range | : | 0-100% |
Resolution | : | 1% |
Accuracy | : | ±2% ( 70-100%, Adult/Pediatric,
Non-Motion, Low perfusion); ±3% ( 70-100%, Neonate, Non-motion); 0-69%, unspecified |
Refreshing Rate | : | 1s |
Pulse Rate | ||
Range | : | 20~300 bpm |
Resolution | : | 1 bpm |
Accuracy | : | ±3bpm ( non-motion) ±5bpm ( motion) |
Refreshing rate | : | 1s |
NIBP | ||
Measurement method | : | Automatic oscillometric method |
Operating mode | : | Manual, automatic, continuous |
Measurement unit | : | mmHg/kPa selectable |
Typical measurement time | : | 20~40s |
Measurement type | : | Systolic, Diastolic Mean Measurement range (mmHg) |
Range of Systolic pressure | : | Adult 40-270 Pediatric 40-230 Neonatal 40-135 |
Range of Diastolic pressure | : | Adult 10-210 Pediatric 10-150 Neonatal 10-100 |
Range of Mean pressure | : | Adult 20-230 Pediatric 20-165 Neonatal 20-110 |
Maximum average error | : | ±5mmHg |
Maximum standard deviation | : | ±8mmHg |
Resolution | : | 1mmHg |
interval | : | 1,2,3,4,5,10,15,30,60,90,120,180,240,480 minutes |
Overpressure protection | : | Software and hardware, double safety protection Cuff |
Pressure range | : | 0-280mmHg |
IBP(Optional) | ||
Channel | : | 2-Channel or 4-Channel |
Measurement Types | : | Systolic, Diastolic, Mean |
Range | : | 0mmHg~300mmHg |
Resolution | : | 1mmHg |
Accuracy | : | ±2% or ±1mmHg, whichever is greater(without sensor) |
Sensitivity | : | 5uV/mmHg/V |
Impedance range | : | 300 to 3000Ω |
C.O.(Optional) | ||
Method | : | Thermodilution |
Range | : | C.O.: 0.1 to 20 L/min TB : 23 to 43⁰C T1 : 0 to 27⁰C |
Accuracy | : | C.O. : ±5% or ±0.1L/min, whichever is greater |
TB, T1 | : | ±0.1⁰C ( without sensor) |
Phasein Multi-gas IRMA AX+Mainstream CO2(Optional) | ||
Gas | : | C02,N2O,HAL,ISO,ENF,SEV,DES with Automatic Identification |
Warm-up time | : | Full accuracy within 20 seconds for IRMA AX+ |
CO2 Accuracy | : | 0-10%: ±(02%+2% of the reading) 0- 15%:±(0.3% + 2% of the reading) |
N2O Accurucy | : | 0-100%:±(2%+2% of the reading |
HAL, ISO, ENF | : | 0-8%:±(0.15%+ 5% of the reading) |
SEV | : | 0-10%±(0.15%+5% of the reading) |
DES | : | 0-22%: ±(0.15% +5% of the reading) |
Agent identification time | : | <20s(typical <10s) |
AWRR range | : | 0-150 bpm |
AWRR accuracy | : | +/- 1bpm |
Apnea 1lme | : | 20s, 25s,30s,35s,40s |
Recorder (Optional) | ||
Horizontal resolution | : | 16 dots/mm (25 mm/s paper speed) |
Vertical resolution | : | 8 dots/mm |
Paper speed | : | 25 mm/s, 50 mm/s |
Number of waveforms channels | : | 3 |
Phasein IRMA Sidestream CO2 (Optional) | ||
Warm-up time | : | Full accuracy within 10 seconds |
Sampling flow rate | : | 50ml/min(±10/min) |
Accuracy | : | ±(0.2% + 2% of the reading) |
Measurement Range | : | 0-15% |
Rise time | : | 200ms, typical at 50ml/min flow rat |
Total response time | : | within 3 seconds ( with 2 m Momoline sampling Line) |
AWRR Range | : | 0-150bpm |
AWRR Accuracy | : | ±1 breath |
Operation Environment | ||
Power | : | AC - 250, 50/60Hz |
Temperature | : | 0-40⁰C |
Humidity | : | 15-85% |
Patient Range | : | Adult, Pediatric, Neonate |