iE 12
Technical Data Sheet: |
||
Acquisition Mode | : | Simultaneous Acquisition of 12-lead ECG |
Inputting Circuit | : | Floating ground input with anti-defibrillation protection circuit |
Display | : | 8.9 inches color High resolution Touch LCD screen with 15 degree Elevation for easy Viewing. |
Display of whole instrument work status, time, heart rate and with back light. | ||
Resolution | : | 1280×768 |
Design | : | Agronomic and Light Weight |
Keyboard | : | Silicon Alphanumeric Keyboard with waterproof design |
Short Keys | : | Multiple Short Keys for quick operations |
Operation Guide | : | On Screen Operation Guide to Check ECG Procedure and coloured lead disconnection display |
Alarm | : | Human voice reminder and visual alarming for lead attachment & noise interference. |
ECG Cable | : | 10 Leads with ECG |
A to D Conversion | : | 24 bit with CMRR >89 dB |
Sampling Rate | : | 1000 Samples/Sec, 8000 Samples/Sec of Pacemaker Detection Channel |
Sampling Frequency | : | 8000 Hz |
Waveform Display | : | 1) Same screen display: 6*2,3*4,12*1(12leads simultaneous display on the same screen) |
2) Split-screen display: 6*2 (6 leads display on the same screen) , 3*4 (3 leads display on the | ||
same screen) | ||
3) Cabrera lead mode | ||
Filters | : | AC, EMG, Anti-Drift ( Baseline Wonder), Low-Pass, High-Pass. |
Storage | : | At least 1500 ECG |
Analysis | : | Complete Interpretation. Exclusive analysis module for children and pediatrics with |
250Hz low-pass frequency, meeting the newest standard of AHAIACC/HRS 2007 | ||
Measurements | : | Ventricular rate, PR interval, QRS time limit, QT/QTC interval, P/QRS/T axis, |
RV5/SV1 amplitude and RV5+SV1 amplitude | ||
HR Range | : | 30 to 300 BPM , Accuracy - +/- 3 BPM |
Rhythm Analysis | : | Up to 300 seconds of rhythm analysis , enabling doctors to find arrhythmia easier. |
Recording Format | : | “Auto/Manual 3X4, 3X4+R, 3X4+3R, 6x2, 6x2+R, 6x2+3R, 12, 12+R, 12+3R,3, 6 & 12channel”, |
“Paper save mode” , “Cabrera mode” , “Arrhythmia monitor mode” and “Cycle print monitor | ||
mode” | ||
Recording Modes | : | Automatic/Manual/Rhythm/R-R Histogram |
Frequency Response | : | 0.05-250 Hz special for pediatric diagnosis. |
ST Segment Measurement | : | ST segment measurement and analysis. |
Paper Speed | : | 5, 6.25, 10, 12.5, 25, 50mm/s, ±5 % |
Sensitivity | : | 2.5,5,10,20,10/5,20/10 mm/mV, Auto Gain (Auto gain for the Automatic mode) |
Noise Level | : | <30 dB |
Calibration Voltage | : | 1mV± 5% |
Power Requirements | : | AC: 100-240V, 50/60Hz |
Operating Temperature Range | : | 10 C to 50 c |
Battery | : | Li-Ion Rechargeable Battery for up to 4 Hours of continuous Operation |
Safety Level | : | IEC60601-1 Class II Type CF |
Printer | : | High resolution thermal array printer |
Recording Paper | : | 210 mm×140 mm×200 p/210 mm×150 mm×200 p fan- fold paper |
Peripheral Port | : | SD Card, USB, LAN and VGA (Optional) |
Communication | : | (Optional ) Interface with PC through PC Communication and printer |
Software & Data Format | : | Wi-Fi . Optional Bar Code Reading Input for Patient Data. |
DICOM, XML, JPG, PDF | ||
Memory | : | Internal memory supporting ECG data and waveforms store and recall. |