Technical Data Sheet:

Acquisition Mode : Simultaneous Acquisition of 12-lead ECG
Inputting Circuit : Floating ground input with anti-defibrillation protection circuit
Display : 8.9 inches color High resolution Touch LCD screen with 15 degree Elevation for easy Viewing.
Display of whole instrument work status, time, heart rate and with back light.
Resolution : 1280×768
Design : Agronomic and Light Weight
Keyboard : Silicon Alphanumeric Keyboard with waterproof design
Short Keys : Multiple Short Keys for quick operations
Operation Guide : On Screen Operation Guide to Check ECG Procedure and coloured lead disconnection display
Alarm : Human voice reminder and visual alarming for lead attachment & noise interference.
ECG Cable : 10 Leads with ECG
A to D Conversion : 24 bit with CMRR >89 dB
Sampling Rate : 1000 Samples/Sec, 8000 Samples/Sec of Pacemaker Detection Channel
Sampling Frequency : 8000 Hz
Waveform Display : 1) Same screen display: 6*2,3*4,12*1(12leads simultaneous display on the same screen)
 2) Split-screen display: 6*2 (6 leads display on the same screen) , 3*4 (3 leads display on the
same screen)
3) Cabrera lead mode
Filters : AC, EMG, Anti-Drift ( Baseline Wonder), Low-Pass, High-Pass.
Storage : At least 1500 ECG
Analysis : Complete Interpretation. Exclusive analysis module for children and pediatrics with
 250Hz low-pass frequency, meeting the newest standard of AHAIACC/HRS 2007
Measurements : Ventricular rate, PR interval, QRS time limit, QT/QTC interval, P/QRS/T axis,
 RV5/SV1 amplitude and RV5+SV1 amplitude
HR Range : 30 to 300 BPM , Accuracy - +/- 3 BPM
Rhythm Analysis : Up to 300 seconds of rhythm analysis , enabling doctors to find arrhythmia easier.
Recording Format : “Auto/Manual 3X4, 3X4+R, 3X4+3R, 6x2, 6x2+R, 6x2+3R, 12, 12+R, 12+3R,3, 6 & 12channel”,
“Paper save mode” , “Cabrera mode” , “Arrhythmia monitor mode” and “Cycle print monitor
mode”
Recording Modes : Automatic/Manual/Rhythm/R-R Histogram
Frequency Response : 0.05-250 Hz special for pediatric diagnosis.
ST Segment Measurement : ST segment measurement and analysis.
Paper Speed : 5, 6.25, 10, 12.5, 25, 50mm/s, ±5 %
Sensitivity : 2.5,5,10,20,10/5,20/10 mm/mV, Auto Gain (Auto gain for the Automatic mode)
Noise Level : <30 dB
Calibration Voltage : 1mV± 5%
Power Requirements : AC: 100-240V, 50/60Hz
Operating Temperature Range  : 10 C to 50 c
Battery : Li-Ion Rechargeable Battery for up to 4 Hours of continuous Operation
Safety Level : IEC60601-1 Class II Type CF
Printer : High resolution thermal array printer
Recording Paper : 210 mm×140 mm×200 p/210 mm×150 mm×200 p fan- fold paper
Peripheral Port : SD Card, USB, LAN and VGA (Optional)
Communication : (Optional ) Interface with PC through PC Communication and printer
Software & Data Format : Wi-Fi . Optional Bar Code Reading Input for Patient Data.
DICOM, XML, JPG, PDF
Memory : Internal memory supporting ECG data and waveforms store and recall.